7. Life phases

7.5.2 Wiring of the lifting column

DIN plug
A = Hall sensor output A (open collector)
B = Hall sensor output B (open collector)
C = Hall sensor
D = Upper limit switch
E = Lower limit switch
Vcc = Power supply (+5V to +24V)
GND = Power supply ground
Motor direction of rotation
DIN plug
Mini-Fit Jr.
1
2
44
Mini-Fit Jr.
A = Hall sensor output A (open collector)
B = Hall sensor output B (open collector)
C = Hall sensor
D = Upper limit switch
E = Lower limit switch
Vcc = Power supply (+5V to +24V)
GND = Power supply ground
PIN 1 + 7
PIN 8 M-
+
-
PIN 2 + 4
PIN 1 M+
-
+
Direction
retract
extend