7. Life phases

7.4.2 RKSlimlift EM

To install the RKSlimlift EM, there are 9x M6 tapped holes
in the top plate 2, (view X) 7 x Ø5.4 mm holes on the bottom
side, and 4 x M8 threaded holes in the base plate 3. The
max. screw depth for M6 in the top plate is 8 mm, and 10
mm in the base plate for M8.
The recommended tightening torque for M6 is max. 10 Nm
and for M8 max. 15 Nm.
Motorised configuration
When connecting the optional controllers, please observe
the designation on the type plate of this RKSlimlift.
Limit switch
The RKSlimlift / RKSlimlift EM is equipped with two limit
switches. These prevent an overrunning of the maximum
lifting height as well as overrunning of the lower stop
position when using controllers intended for the RKSlimlift
/ RKSlimlift EM. When using another controller or direct
supply of current, the lifting columns can extend beyond the
limit switches and lead to their destruction.
Manual configuration (only RKSlimlift)
Adjustments are performed manually using a crank handle.
Operation
Insert the crank handle in the receptacle.
Turn to the right to raise the lifting column.
Turn to the left to lower the lifting column.