Herunterladen Inhalt Inhalt Diese Seite drucken

Important Remarks; Declaration Of Conformity; Technical Specifications - V2 JET650 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 53

IMPORTANT REMARKS

For any installation problems please contact V2 ELETTRONICA
TEL. (+39) 01 72 81 24 11
V2 ELETTRONICA has the right to modify the product without
previous notice; it also declines any responsibility to damage
or injury to people or things caused by improper use or wrong
installation.
PLEASE READ THIS INSTRUCTION MANUAL VERY
CAREFULLY BEFORE INSTALLING AND PROGRAMMING YOUR
CONTROL UNIT.
• This instruction manual is only for qualified technicians, who
specialize in installations and automations.
• The contents of this instruction manual do not concern the
end user.
• Every programming and/or every maintenance service should
be done only by qualified technicians.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE WITH
THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1 (Machinery safety. electrical equipment of
machines, part 1: general rules)
EN 12445
(Safe use of automated locking devices, test
methods)
EN 12453
(Safe use of automated locking devices,
requirements)
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply. The standards require a separation of
the contacts of at least 3 mm in each pole (EN 60335-1).
• To connect flexible or rigid pipes, use pipefittings having the
IP55 insulation level.
• Installation requires mechanical and electrical skills,
therefore it shall be carried out by qualified personnel only,
who can issue the Compliance Certificate concerning the
whole installation (Machine Directive 98/37/EEC, Annex IIA).
• The automated vehicular gates shall comply with the
following rules: EN 12453, EN 12445, EN 12978 as well as
any local rule in force.
• Also the automation upstream electric system shall comply
with the laws and rules in force and be carried out
workmanlike. V2 Elettronica declines any responsibility in
case of automation upstream electric system not complying
with the laws and rules in force and not carried out
workmanlike.
• The door thrust force adjustment shall be measured by
means of a proper tool and adjusted according to the max.
limits, which EN 12453 allows.
• We recommend to make use of an emergency button, to be
installed by the automation (connected to the control unit
STOP input) so that the gate may be immediately stopped in
case of danger.
• The use of JET65O in dusty, saline or explosive environment
is forbidden.

DECLARATION OF CONFORMITY

V2 ELETTRONICA SPA declares that the series of JET-24V
actuators are in conformity with the provisions of the following
EC directives:
73/23/EEC
electrical safety
93/68/EEC
electromagnetic compatibility
99/05/EEC
radio directive
98/37/EEC
machine directive
Note: Declares that the above mentioned devices may not be
operated until the machine (automated gate) is identified, CE-
labeled, and declared to be compliant to the specifications of
Directive 89/392/EEC and following modifications.
The person in charge for the machine start-up must provide the
following records:
• Technical specification paper
• Declaration of conformity
• CE-labeling
• Testing record
• Maintenance record
• Operation manual and directions
Racconigi 10 / 09 / 2003
V2 ELETTRONICA SPA legal representative
A. Livio Costamagna

TECHNICAL SPECIFICATIONS

Power supply
Average speed
Line absorption
Absorbed power
Full load current
Working temperature
Max accessories load 24V
Protection fuses
Protection
Working cycle
Motor weight
17
JET650
JET650-120V
230VAC 50Hz 120VAC 60Hz
120 mm /s
120 mm /s
1A
2A
230W
240W
8A
-20 ÷ +50 °C
10W
10W
F1 = 1,25A
F1 = 2A
DELAYED
IP20
30 %
10 Kg