Herunterladen Diese Seite drucken

Siemens 5TC1 Series Bedien-Und Montageanleitung Seite 8

Jalousiesteuerung
Vorschau ausblenden Andere Handbücher für 5TC1 Series:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
Warning
Attention: Electrical equipment must be installed and fitted by qualified
electricians only.
The shutter control system has been developped for the switching of motors for
blinds and roller shutters. Do not use the system for switching other types of loads.
For parallel connection of blind/shutter motors, the instructions of the motor manu-
facturers must be observed. The motors might otherwise be irreparably damaged.
Use only blinds or roller shutters equipped with limit switches (mechanical or
electronic). Observe the instructions of the motor manufacturers.
Observe the instructions of the motor manufacturers as to switch-over delay and
maximum duty cycle.
The shutter control system has been developped for the automatic operation of window
blinds and shutters. Using the control for other applications (e.g. roller shutter doors
and gates) may involve risks.
The user must exclude these risks by installing further suitable safety devices (e.g.
light barriers).
14
GB
Connection
The insert is connected as shown in the figure on the left.
The insert  is installed in a box acc. to DIN 49073 (deep box recommended).
The connecting terminals of the insert must be at the bottom.
The
shutter control timer
or the
shutter control timer ' Komfort'
with frame ƒ onto the insert.
The electrical contact is established through connector „.
The additional pins … of the
shutter control timer ' Komfort'
make contact with the sensor
cable terminal in the insert.
The sensor itself is connected to the screw terminals.
‚ is plugged together
15

Werbung

loading