Herunterladen Diese Seite drucken

Siemens 5TC1 Series Bedien-Und Montageanleitung Seite 10

Jalousiesteuerung
Vorschau ausblenden Andere Handbücher für 5TC1 Series:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
Technical characteristics
Rated voltage
Contact rating
Relay contacts
Pulse duration
Switch-over delay for
continuous run
Connecting terminals
Supply-line circuit breaker
Ambient temperature
Storage temperature
18
: AC 230 V, 50 Hz, N conductor required
: 1 motor of 1000 W max.
: 2 n.o. contacts at mains potential
(interlocked)
: Control timer
up and down movement: ca. 2 minutes
Control timer 'Komfort'
up and down movement: ca. 2 minutes (preset)
adjustable between: 1 second – 12 minutes,
the upward movement cannot be shorter than
2 minutes
: electronic interlocking ensured by timer
: screw-type terminals for 2.5 mm² or
2 x 1.5 mm² max.
: 16 A max.
: +5 °C ... +35 °C
: -10 °C ... +60 °C
GB
General information
Defective devices are to be sent to the competent branch of Siemens AG.
For further relevant information contact our Technical Support:
'
+49(0) 180 50 50 222
7
+49(0) 180 50 50 223
*
adsupport@siemens.com
19

Werbung