2.1.4 Ventilation pipe
A dedicated ventilation pipe must be connected
to the Aqualift F. This ventilation pipe should be
open to the ambient air in order to equalize any
pressure which may build up in the system. The
size of the ventilation pipe shall be at least DN 70.
To prevent any odour nuisances from the ventila-
tion pipe – it should be run to outside ambient air
(outdoors). Connect the ventilation pipe as seen
in Illustration 3.
To drill out the ventilation hole use the KESSEL
core hole drill attachment (Article Number 50101).
The hole should be carefully drilled and with pre-
cision
2.2 Installing / removing the pump(s)
The pump is held in place with the three locking
levers as seen in illustration 4. The pump's pres-
sure outlet is locked in place with a closure clasp
(illustration 4). After connecting the cable and the
air pressure hose to the control unit (see instal-
lation and operation manual of the control unit)
the system is ready to be commissioned.
2. Installation
e
ill. 3
a = securing nut
b = base washer
c = Noise reduction gasket
d = threaded rod
e = anti-vibration matt
f = dowel