- reconnect to the power supply keeping the Stop/Prog button pressed;
- after 3 seconds LED L1 lights up;
- keeping the Stop/Prog button pressed, shift dipswitch 9 from Off to On (if the dipswitch is On put it to Off
and then to On again);
- LED L1 starts to blink;
- still keeping the Stop/Prog button pressed, shift dipswitch 9. The LED changes its blinking rhythm;
- fast blinking means enhanced slowdown
- slow blinking means normal slowdown (factory setting);
- after having made the selection, release the Stop/Prog button; the control unit makes the appropriate sto-
rage and starts up normal operation.
FINAL TEST AND INSPECTION
Always carry out a final test and inspection after having completed all the programming.
- Check correct operation of the protective devices (anti-crushing system, stop pushbutton, photocells,
safety edges, etc.).
- Check correct operation of the warning devices (flashing lights, open gate warning light, etc.).
- Check correct operation of the control devices (P/P button, remote controls, etc.).
IMPORTANT RECOMMENDATIONS CONCERNING INSTALLATION
- Only qualified personnel having the legal requirements must install the automation according to the prin-
ciples of good workmanship and in conformity with the machinery directive 98/37/CE and standards EN
12453 and EN 12445.
- Check that the existing structures (posts, hinges, leaves) are stable in relation to the forces developed by
the motor.
- Check that suitably robust limit stops have been installed for end of gate opening and closing.
- Check the state of the cables that are already present in the system.
- Analyse the hazards connected with the automation system and adopt the necessary safety and signal-
ling devices accordingly.
- Install the commands (e.g. the key selector) so that the user is not placed in a hazardous area when using
them.
- Upon completion of the installation, test the safety, signalling and release devices of the automation
system several times.
- Apply the CE label or plate with information regarding the hazards and identification data on the auto-
mation.
- Give the end user the instructions for use, the safety recommendations and the CE declaration of con-
formity.
- Ensure that the user has understood the correct automatic, manual and emergency operation of the auto-
mation system.
- Inform the user in writing (e.g. in the instructions for use) of any unprotected residual risks and of fore-
seeable misuse.
- Inform the user in writing (in the use instructions for example):
Of possible non secluded residual risks and of foreseeable improper use.
To disconnect the power supply when cleaning the area that is automated or when performing
small maintenance operations (e.g.: repainting).