Type 3
AUTOMATION SYSTEM WITH 1 MOTOR WITHOUT LIMIT SWITCHES *
Prior to programming:
- check that the dipswitch (det. 11 of fig.1) No. 11 is in the OFF position
- check that the motor has been connected to M1 (terminals 1 - 2 and 3)
* anti-crushing module MAS200 should only be connected after having carried out the self-learning
procedure.
Programming:
1 - Cut off the power supply to the control unit.
2 - Position the gate halfway along its course of travel
3 - Press the STOP/PROG key (det. 19 of fig.1)
4, 5 and 6 - Power the control unit keeping the STOP/PROG key pressed until the LED L1 (det. 3 of fig. 1)
lights up.
7 - Press the P/P button (det. 18 of fig. 1); the motor starts to close the gate, if the motor turns in the rever-
se direction, cut off the power supply, invert the phases of the motor and repeat the procedure.
8 and 9 -When the gate hits the stop, press the button P/P; the motor stops and then automatically starts
to open the gate.
10 - Press the button P/P when the gate is fully open.
11 - Allow the desired pause time to elapse before closing again.
12 - When the desired pause time has elapsed, press the button P/P; the motor starts to close the gate.
13 - Press P/P when the gate is fully closed.
14 - The LED L1 goes out indicating the end of programming.