Herunterladen Inhalt Inhalt Diese Seite drucken

Telcoma T 200 Installationsanweisungen Seite 62

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 69
GB
TAB.2
N.
Function
Dip
1
2
1
Step-by-step input
2
and radio channel
1
mode
2
1
2
3
4
3
4
Jolly input mode
3
4
3
4
Pre-flashing light
5
Re-closure
6
Photo test
7
Release thrust
8
Slowdown
9
Closing thrust
10
Mode
11
Incorp. radio
12
58
OFF ON
Desciption
Open - Stop - Close
Open - Close
Open
Condominium function
Open – Close
(Cut out of opening control)
J1=Open pushbutton
J2=Close pushbutton
J1=Thermostat
J2=Photocell 3
2
nd
pair of limit switches
J1=FCA J2=FCC
J1=Clock
J2=Photocell 3
Cut out
Connected
Cut out
Connected
Cut out
Connected
Cut out
Connected
Cut out
Connected
Cut out
Connected
Control unit for 1
motor or 2 in
parallel
Control unit for 2
independent
motors
Notes
During opening, upon pressing the P/P button the gate stops, pres-
sing it again the gate closes. During closing, upon pressing the P/P
button the gate stops, pressing it again the gate opens.
During opening, upon pressing the P/P button the gate stops for a
few seconds and then closes. During closing, upon pressing the P/P
button the gate stops for a few seconds and then opens.
During opening, pressing the P/P button has no effect. During the pause,
pressing the P/P button has no effect. During closing, upon pressing the
P/P button the gate stops for a few seconds and then opens.
During opening, pressing the P/P button has no effect. During the pause,
upon pressing the P/P button the gate closes. During closing, upon pres-
sing the P/P button the gate stops for a few seconds and then opens.
J1 = opening pushbutton
J2 = closing pushbutton
Use NO contacts or pushbuttons
J1=Ambient thermostat for compensating working times (optional).Open con-
tact=normal times, closed contact=longer times.
J2=Input for third photocell;it only activates during opening and forces closing.
Use a NC contact.
For installations where 4 limit switches (gate stops) are mounted. Connect the
motor M1 limit switches to the inputs FCC and FCA. Connect the motor M2 limit
switches to the inputs J1 and J2. Use NC contacts.
J1=Clock input; this closes the gate when the contact is opened and opens it when
the contact is closed. J2=input for the third photocell; it only activates during ope-
ning and forces closing. Use NC contacts.
The flashing light is powered at the same time as the motor.
The flashing light is powered 5 seconds before any movement.
After one complete opening, the control unit only closes again with
a manual control.
After one complete opening, the control unit closes automatically
after the programmed pause time.
See text in Fototest section.
See text in Fototest section.
Function cut out.
The release thrust has the function of releasing the electric lock. The leaf with M1
gives a short thrust in the closing direction before starting to open.
There is no slowdown in the last part of travel.
With the slowdown function connected, the motor halves its speed
towards the end of every gate movement. This function may not work
properly with hydraulic motors.
No closing thrust is carried out.
The control unit ends gate closure with a short full-power thrust on
motor M1.
The outputs M1 and M2 work in parallel and the pedestrian control
partially opens/closes the gate leaf/s. For single motor control, see
the section "Programming the times".
The outputs M1 and M2 are independent and the pedestrian con-
trol fully opens and closes the leaf with motor M1. For motor con-
trol, see the section "Programming the times".
When the incorporated receiver is NOT used, it MUST be cut out.
Incorporated receiver enabled.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis