Comfort Control
7.
Troubleshooting
7.1.
Error message display
All repair and servicing work must be carried out exclusively by persons or
organizations expressly authorized to do so by the manufacturer.
The error message appears as the two right-hand
figures in the session-time display (e.g. 92).
The "
service
" symbol
the error message.
The control system can operate for as long as
service
the "
" symbol
The error message is displayed alternately with the
sauna program.
No. Error
85
Broken lead on main board/display board.
86
Broken lead on infrared temperature-sensor.
87
Short-circuit on infrared temperature-sensor.
88
Heating element defective.
95
Broken lead on cabin-temperature sensor.
96
Broken lead on limiter temperature sensor.
97
Safety temperature limiter (STL) interrupted.
98
Short-circuit on cabin-temperature sensor.
99
Short-circuit on limiter temperature sensor.
92
Maintenance required: vaporizer deferring.
50701117/10.05
flashes together with
flashes.
Error remedy
Disconnect control system.
Do not enter cabin!
'
Contact customer service.
Deferring the vaporizer.
'
See section 9.1.