5
Electrical installation
Wiring of the feedback system
Encoder connection
Via the 9−pole Sub−D−plug X8, you can connect the following encoders:
Incremental encoder (TTL encoder)
ƒ
with two 5 V complementary signals (RS−422) that are electrically
shifted by 90°.
with zero track that can be connected optionally.
Sin/cos encoder (singleturn or multiturn rotary transducer)
ƒ
with supply voltage (5 ... 8 V).
with serial communication.
The initialisation time of the axis module is extended to approx. 2 s.
The controller supplies the encoder with voltage.
Use C0421 to set the supply voltage V
voltage drop [DV] on the encoder cable:
DU ^ 2 @ L
DV
Voltage drop on the encoder cable [V]
L
Cable length [m]
L
R/m
Ohmic resistance per meter of cable length [W/m]
I
Encoder current [A]
G
(
Stop!
Observe the permissible supply voltage of the encoder used. If the
values in C0421 are set too high, the encoder can be destroyed!
130
[m] @ R m [W m] @ I
L
G
(5 ... 8 V) to compensate, if required, the
CC
[A]