3.2

Rated data

Rated data
Output power 400 V mains
Data for operation with upstream power supply
module on mains voltage
DC−bus voltage
DC−bus current
Rated output current at 4 kHz
(causes a heatsink temperature of 70°C at an
ambient temperature of 20°C)
Rated output current at 8 kHz (at an ambient
temperature of 20°C it causes a heatsink
1)
temperature of 70°C)
Max. output current
(acceleration current)
Continuous current at standstill
(holding current at 90°C, 4 kHz)
Short−time standstill current
(holding current at 90 °C, 4 kHz)
Short−time standstill current
(holding current at 70 °C, 4 kHz)
Short−time standstill current
(holding current at 70 °C, 8 kHz)
Power loss (operation with
rated current at 4 kHz / 8 kHz)
Max. output frequency
Mass
1)
If the heatsink temperature reaches 70°C, the switching frequency automatically changes to
4 kHz.
2)
The indicated temperature is the measured heatsink temperature (C0061).
L
Application software:
EDKCSCX064 DE/EN/FR 4.0
Type
S
[kVA]
rated
V
mains
V
DC−bus
I
DC−bus
I
[A]
r
I
[A]
r
I
max
I
0,eff 4 kHz
I
0,eff 4 kHz
2)
I
0,eff 4 kHz
2)
I
0,eff 8 kHz
2)
Total
Inside the
P
[W]
loss
device
Heatsink
f
[Hz]
out
m [kg]
S = Speed & Torque
M = Motion
l
Technical data
Axis module
ECSxL004
1.3
[V]
400
480
400
[V]
[A]
2.5
2.0
4.9
2.0
1.6
4.0
1.4
1.1
2.7
[A]
4.0
[A]
2.0
1.6
4.0
[A]
2.3
[A]
3.0
[A]
1.5
27.3
13.3
14.0
approx. 2.4
P = Posi & Shaft
A = Application
Rated data
ECSxL008
ECSxL016
2.6
5.3
480
400
480
15 ... 770
3.9
9.8
7.8
3.2
8.0
6.4
2.2
5.3
4.2
8.0
16.0
3.2
8.0
6.4
4.6
9.1
6.0
12.0
3.0
6.0
46.3
84.7
17.3
20.7
29.0
64.0
600
3
91