Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting Information - Dometic BLUTEC 40d Betriebs-, Wartungs- Und Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 68
FINDING MALFUNCTIONS
The aim of the following information is to help
identify and correct any malfunctions and
problems that might occur during use. Some
of these problems may be solved by the user,
while for all the others specific technical
Problem
When the starter button is
pressed the control panel does
not light up
When the starter button is
pressed the unit does not start
The starter motor turns, but the
unit does not start
The unit tends to shut down

TROUBLESHOOTING INFORMATION

Cause
The power cables are
disconnected or they do not
provide a continuous supply
Battery low
The power cables are
disconnected or they do not
provide a continuous supply
The inverter is broken
The starter motor does not turn
electrical power disconnected
Battery low
The power cables are
disconnected or they do not
provide a continuous supply
The inverter is broken
Malfunction in the pump power
supply
Engine malfunction
Injectors dirty or faulty
Cooling air/water pipe blocked
Sea water pump rotor worn
The inverter is broken
Malfunction in the pump power
supply
Injectors dirty or faulty
Air filter blocked
Cooling air/water pipe blocked
Oil level too high
Sea water pump rotor worn
Voltage required higher than 3,5
kW
knowledge or abilities are required, so that
they must only be carried out by qualified
technicians of proven experience in the spe-
cific field of operation.
Remedy
Contact the service department
Change the battery
Contact the service department
Contact the service department
Contact the service department
Press the restore button to
reconnect the electrical power.
Change the battery
Contact the service department
Contact the service department
Contact the service department
Contact the service department
Contact the service department
Check the cooling air/water pipe
and clean it if necessary
Replace the rotor (see "Changing
the water pump rotor")
Contact the service department
Contact the service department
Contact the service department
Clean the air filter
Check the cooling air/water pipe
and clean it if necessary
Check the oil level, and remove
excess oil if necessary (see "Check
oil level")
Replace the rotor (see "Changing
the water pump rotor")
Decrease the required voltage load
- 29 -
GB
User manual

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis