Troubleshooting

10
Troubleshooting
Fault
Cause
The control panel
Starter battery is flat.
does not come
Power cable is disconnected or the
on when the
plug is removed.
on/off switch is
The fuse (if available) is blown.
pressed.
The starter does
Starter battery is flat.
not work when
The main switch is at "0".
the start button is
pressed.
Internal board is damaged.
Starter is not receiving any power.
The starter turns
No petrol.
but the genera-
Too much oil in the engine.
tor does not start.
Spark plug is not receiving any power. ➤ Check the electric connec-
Carburettor is not receiving any pet-
rol.
Air intake is blocked.
Inverter is damaged.
Power cable is disconnected or the
plug is removed.
The generator
Too much oil in the engine.
tends to go off.
Load is over 6,2 kW.
Carburettor is not receiving any pet-
rol.
Air intake is blocked.
Inverter is damaged.
Electromagnet (inverter) is blocked.
Air filter is dirty.
The generator is
Inverter is damaged.
running but does
RPM too low.
not supply any
voltage.
46
Remedy
➤ Charge the starter battery.
➤ Contact an authorised work-
shop.
➤ Charge the starter battery.
➤ Set the main switch to "I" or
"1".
➤ Contact an authorised work-
shop.
➤ Fill up with petrol.
➤ Drain the oil.
tions.
➤ Clean the carburettor.
➤ Check the air filter (see chap-
ter "Servicing the air filter
(fig. 7, page 5)" on page 44).
➤ Contact an authorised work-
shop.
➤ Drain the oil.
➤ Switch off the consumers.
➤ Clean the carburettor.
➤ Check the air filter (see chap-
ter "Servicing the air filter
(fig. 7, page 5)" on page 44).
➤ Contact an authorised work-
shop.
➤ Check the output wiring con-
nection
➤ Contact an authorised work-
shop.