Replacing the fleece filter bag/dust
Close the suction connection
Illustration
 Close the suction connection, see wet
vacuuming.
Exchange the fleece filter bag
Illustration
 Release and remove the suction head.
 Pull out the fleece filter bag on the
flange towards the top.
 Tightly close the fleece filter bag with
lock cap.
 Dispose of the fleece filter bag accord-
ing to the local provisions.
 Insert the new fleece filter bag.
 Insert and lock the suction head.
Replace the disposal bag
Illustration
 Release and remove the suction head.
 Put the disposal bag over.
 Tightly close the disposal bag with ca-
ble tie underneath the opening.
 Remove disposal bag.
 Dispose of the disposal bag according
to the local provisions.
 Insert the new disposal bag.
 Pull disposal bag over the container.
Make sure that the marking line is situ-
ated within the container and both ven-
tilation holes are positioned at the back
of the container.
 Insert and lock the suction head.
Clean/replace the cooling air filter
Illustration
 Allow device to cool down.
 Release the cooling air flaps with
screwdriver and swivel them out.
 Clean (vacuum, wash) or replace the
cooling air filter.
 Fold in the cooling air flaps and snap
them in place.
bag
Cleaning the electrodes
 Release and remove the suction head.
 Clean the electrodes with a brush.
 Insert and lock the suction head.

Troubleshooting

DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
 Check the receptacle and the fuse of
the power supply.
 Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
 Turn on the appliance.
Suction turbine turns off
 Empty the container.
 Insert flat folded filter.
Suction turbine does not start again
after the container has been
 Turn off the appliance and wait for 5 sec-
onds, turn it on again after 5 seconds.
 Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
 Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
 Replacing the full fleece filter bag.
 Replace the filled disposal bag
 Ensure the filter cover properly locks
into place.
 Replace the flat pleated filter.
 NT 50/1 only:
Check drain pipe for leaks.
– 7