10.1 Quarterly
NOTICE
Risk of damage to unit if incorrect
cleaning agent is used.
 Only clean the covers using water.
 Do not use aggressive cleaning agents.
 Do not clean the covers in a dishwasher.
NOTICE
Lamella may break if cleaned
incorrectly.
 Take care when cleaning. Do not
exercise force when opening, shutting
or bending the lamella.
Check the air filter quarterly as follows.
1. Evenly pull designer cover [7] out of the
housing [2].
2. Remove air filter retaining spring and then
the air filter [6].
Slightly dirty air filter: Clean the filter
using clear water and allow it to dry.
Very dirty air filter: Replace filter with a
new one.
3. In the case of severe contamination of the
air channel, the complete air channel and
all housing components should be cleaned
with a vacuum cleaner. To do this, remove
the cover [5] and the internal shutter [4].
Release internal shutter from the locking
hooks [4.1]/[4.2] ( Chapter 8) and
remove it.
4. Clean all components.
5. Reinsert the internal shutter [4]. The
shutter must engage properly.
6. Locate the cover [5] in position and secure
it with the housing locking lever  Chap. 8.
7. Insert air filter [6] in the round housing
recess and use the retaining spring [9]
to secure it to the two cover domes [4].
This involves pulling the retaining springs
apart slightly at the ends and sliding it over
the domes.
8. Fit designer cover [7]. The four pins of the
designer cover must engage easily in the
cover's [5] domes.
10. Cleaning, filter change │ UK
10.2 Every 2 years
For reasons of hygiene, the air filter should
be exchanged for a new one every 2 years.
Depending on the system
configuration, use an air filter of the
G2 or G3 filter class.
11. Accessories
Accessories / Product type
ALDF 125/160 G2
Replacement filter, filter class
G2, 5 items per packing unit
ALDF 125/160 G3
Replacement filter, filter class
G3, 5 items per packing unit
In case of questions, please contact:
Maico Elektroapparate-Fabrik GmbH
Steinbeisstraße 20
78056 Villingen-Schwenningen, Germany
Tel. +49 7720 694 445
Fax +49 7720 694 175
E-mail: ersatzteilservice@maico.de
12. Disposal
The unit and the packaging contain parts that
can be recycled, and should not end up in the
domestic waste.
Dispose of the packaging material in an
environmentally-friendly way, in compliance
with the regulations valid in the country where
you are.
Dispose of the air filter in an
environmentally-friendly way, in compliance
with the regulations valid in the country where
you are.
At the end of its service life, dispose of the
unit in an environmentally-friendly way, in
compliance with the regulations valid in the
country where you are.
Article no.
0093.0079
0093.0080
9