FUSE CHECK/REPLACEMENT/RESET

1.
Drive the machine on a level ground and engage the
parking brake.
2.
Turn the ignition key (82) to "0".
3.
Open the hood (7).
4.
Disconnect the battery negative connector (43).
Lamellar fuse check/replacement
1.
Remove the fuse box cover (46).
2.
Check/replace the relevant fuse among the following (Fig.
18):
(A):
F1 main fuse (key circuit) (15 A)
(B):
F2 fi lter shaker motor fuse (25 A)
(C):
F3 manual vacuum system fuse (40 A) (optional)
(D):
F4 vacuum system motor fuse (30 A)
(E):
F5 horn and pivoting light fuse (10 A)
(F):
F6 working light fuse (10 A) (optional)
3.
Remove the electrical component box cover (50).
4.
Check/replace the following fuse (Fig. 19):
(A):
FT drive system fuse (70 A)
5.
Remove and check/replace the following fuse (63):
FR charging system fuse (70 A)
Fuse check
1.
Check one of the following fuses (Fig. 18) for deactivation:
(G):
FA main broom motor fuse (30 A)
(H):
FB side broom motor fuse (10 A)
Reset any deactivated fuse, when the component that
caused deactivation has fully cooled down.
2.
Close the hood (7).