8.2
Meaning of the LED display
LED display
Green LED off.
Green LED lights up.
Green LED off
(pressing operation
in progress).
Green LED flashes.
Red LED (3) flashes.
Red LED lit up.
Red and green LED
flash alternately.
8.3

Performing the pressing operation

CAUTION!
Danger of crushing!
There is a risk that fingers and hands will be crushed.
Therefore:
– Keep body parts and foreign objects away from the press jaws during the pressing
– Do not hold the jaw levers with your hands during the pressing operation.
Status/cause
The device is switched
off.
Ready for operation.
Automatic press cycle is
on, device ends the
pressing operation
automatically.
Insufficient battery
charge.
Device not within the
temperature range.
Device fault
Service interval
reached.
operation.
Measure
Briefly press the start button (see section
7.7).
Charge or replace battery.
The device only works within a
temperature range from -10 to +50 °C. If
the red LED is flashing, the device must
be moved into a warmer or colder area.
The device can be warmed to operating
temperature by means of dry runs.
Press the start button. If this is
unsuccessful, the press device is
defective.
Send the device to a specialist workshop.
NOTE:
The pressing operation may not have
been completed; please check and repeat
if required.
Take the press device to be serviced.