Pos: 112 /Gartentechnik/KDS Anlage INVIKTA/Alarm INVIKTA @ 12\mod_1253712462689_121.doc @ 75826 @
28.

Alarm

Alarm
Level
OFA First Alarm (time >70%)
OFA Second Alarm (time
=100%)
Flow Rate
System Error
Calibration Function
29.

Default parameters:

Language = UK
Set Point value= 7,4 pH; 750 mV (Rx)
Dosing Method = Acid; Low (Rx)
Time OFA = OFF
Calibration = Full
Flow Input= OFF
30.

To restore Default parameters run Following steps:

Power off Pool Basic unit
Keeping Press UP and DOWN Key switch on the Power.
The unit will flash Init.default__no
Press up Init.default__Yes
Enter Key to restore Default parameters.
Pos: 113 /Alle Produkte/Überschriften/H1 Entsorgung @ 7\mod_1196625583904_121.doc @ 41547 @
31.

Disposal

Pos: 114 /Alle Produkte/Entsorgung/ENT BAS - Kein Hausmüll @ 10\mod_1243521970991_121.doc @ 63330 @
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return
system provided. Disable the unit beforehand by cutting off the cables.
Pos: 115 /Alle Produkte/Dummy_module/===== Seitenwechsel ===== @ 0\mod_1125648978015_0.doc @ 1631 @
40
Display
level____7,2_ph
ofa_alarm__7,2_ph
ofa_stop___7,2_ph
Flow_______7,2_ph
Parameter_error
Error_7_ph Error_4_ph
Error_465_mv
Relais
Alarm Relay Close
Alarm Relay open
Alarm Relay Close
Alarm Relay open
Alarm Relay Open
Alarm Relais geöffnet
Abhilfe
Push Enter Key to open Alarm
Relay
Restore Product tank
Push Enter Key to reset
Push Enter Key to reset
Restore Flow Rate
Press Enter Key to replace
Default parameter
Destroy Unit
Restore Probe or Buffer
solution and repeat calibration
function