23.

Instruction Setting

23.1

Functions:

Calibration (Press Cal Key
Select the calibration routine pH or Redox by Up or Down key.
Standard Routine calibration pH probe is 7 and 4 buffer solution and Redox 465 mV buffer solution
Set Point (Press Set Key
Press Set Key and choose SetPoint and adjust value with Up or Down Key before press Enter and
confirm.
Sp_750mv___700_mv_
Sp_7.4ph____7.6_ph_
Press Cal and Set Key (both)
23.2

Program_Menu (Press Enter to set the following Item)

Language_ (It's possible to have 5 language EN, IT, SP, DE, FR)
Redox_Measure
setpoint___750_mv (Adjust value with enter and up or down key) It's possible to adjust from
0 to 1000 mV value for Redox
sp_type___low (Adjust value LOW or HIGH)
ofa_time_000_min (Adjust value OFF or set Time)
alarm_band__000_rx (Adjust value from 100 to 300 mV )
ph_Measure
setpoint____7.4ph (Adjust value with enter and up or down key) It's possible to adjust from 0
to 14 pH value.
sp_type___acid (Adjust value ACID or ALKA)
ofa_time_000_min (Adjust value OFF or set Time)
alr_band__000_ph (Adjust value from 1 pH to 3 pH)
Temp__25*C_(Adjust value with enter and up or down key) pH measure only.
Flow_(Adjust value with enter and up or down key Enable or Disable)
It's possible to enable(ON) or disable (OFF) signal input
Calibration_probe (Adjust value with enter and up or down key)
Full (pH 7 and 4, Redox 465 mV buffer solution)
Easy (pH 7, Redox 465 mV buffer solution)
Off (Disabled)
Password (Adjust value with enter and up or down key, standard value 0000)
23.3
Exit______save
(Adjust value with up or down key and confirm with enter key)
Save and escape Program setup with ESC key
23.4
priming_____700mv
Priming Pump Keep Press UP Key for 1 seconds
23.5
priming_____7.2ph
Priming Pump Keep Press Down Key for 1 seconds
36
for 3 Seconds):
for 3 Seconds)
for 5 Seconds and run Program Setup:
and priming redox pump