1.2 Desk microphone PA-4300PTT
(separately available accessory)
31 DIP switch CHIME;
in the position ON, the chime will sound first
when the button TALK (37) is pressed
32 DIP switch PRIORITY;
OFF:
An announcement will be made
in the PA zones selected at the
amplifier.
ON:
All
zone
outputs
switched on as long as the but-
ton TALK (37) is pressed.
33 Switch MASTER / SLAVE to define the priority
when multiple microphones PA-4300PTT are
used
SLAVE:
Other microphones switched to
MASTER will take priority.
MASTER:
The microphone will take prior-
ity over the microphones that
are switched to SLAVE.
34 RJ-45 jack OUTPUT for connection to the
jack PA-4300PTT (30) of the amplifier or to
the jack LINK (35) of a different PA-4300PTT
35 RJ-45 jack LINK to connect another micro-
phone PA-4300PTT
(a maximum of 3 interconnected micro-
phones can be connected to the amplifier)
36 Microphone cartridge with windshield
37 Button TALK; to make an announcement,
keep the button pressed and, if applicable,
wait for the chime to sound; when the button
is pressed, the green LED TALK above the
button will light up
The red LED BUSY will indicate any an-
nouncements that are being made via a dif-
ferent PA-4300PTT.
1.3 Zone paging microphone PA-2500RC
(separately available accessory)
38 Jack 24 V for additional power supply via a
power supply unit with a low voltage plug
5.5/2.1 mm (outer / inner diameter); observe
the polarity: centre contact = ⊕
The additional power supply unit will be
required when the amplifier does not provide
sufficient power [when the LED LOW
POWER lights up, e. g. because more than 3
PA-2500RC are connected or the cable is
very long].
39 RJ-45 jack INPUT to connect another PA-
2500RC
40 RJ-45 jack LINK for connection to the jack
PA-2500RC REMOTE RECEIVER (29) of the
amplifier or to the jack INPUT (39) of a differ-
ent PA-2500RC
41 DIP switches for bus address and line termi-
nation
Prior to connecting the PA-2500RC to the
amplifier, use the switches 1 – 5 to set differ-
ent address numbers at all the PA-2500RC to
be connected (
chapter 7.5.1).
At the final PA-2500RC of the microphones
connected in a chain, set the switch 6 (TER-
MINATION) to the position ON to activate the
terminating resistor.
42 DIP switches
Switch 1 (PRIORITY) – In the position ON,
the PA-2500RC will take priority over the
other PA-2500RC for which this function has
not been activated and will be able to inter-
rupt their announcements
Switch 2 (COMPRESSION) – In the position
ON, the dynamics of the microphone signal
will be attenuated to reduce distortions when
announcements at a high volume are being
made
Switch 3 (CHIME ON / OFF) – In the position
ON, a chime will sound first when the button
TALK (46) is pressed:
4-tone chime when switch 4 is in the position
ON;
will
be
2-tone chime when switch 5 is in the position
ON and switch 4 is in the upper position
Switch 6 – Definition of the amplifier to be
used with the zone paging microphone:
Position ON
Upper position
43 Control CHIME to adjust the volume of the
chime
44 Control MIC to adjust the volume of the
announcements
45 Microphone cartridge with wind windshield
46 Button TALK; to make an announcement,
keep the button pressed and, if applicable,
wait for the chime to sound; when the button
is pressed, the LED above the button will light
up
47 Button RECALL to save or call up a group of
frequently required zones
To save the selected zones, keep the button
pressed until the LED POWER (49) stops
flashing.
To call up the saved group, briefly press the
button. When the button is pressed again, the
previous selection will apply.
48 Zone selection buttons
1 – 10: zones Z 1 – 10 (PA-2510D)
1 – 20: zones Z 1 – 20 (PA-2520D)
ALL:
all zones (of the corresponding row of
buttons)
When the button is pressed again, the
previous selection will apply.
49 Status indicator LEDs
POWER – power indicator; will flash when
zones are being saved with the button
RECALL (47)
BUSY – will light up during an announce-
ment; will flash when announcements of a
higher priority are being made
MIC / FAULT – will indicate microphone failures
LOW POWER – will indicate insufficient sup-
ply voltage
SIGNAL – will light up when a signal from the
microphone or the chime is available
50 Operating buttons to call up saved messages
for the insertion module PA-1120DMT
Important: The module can only be remote-con-
trolled by these buttons when the left switch in the
insertion compartment of the amplifier is in the right
position ON (
figure 7). Only change the position
of the switch when the amplifier is disconnected
from the power supply; otherwise, the change will
not be adopted.

2 Safety Notes

The unit corresponds to all relevant directives of
the EU and is therefore marked with
WARNING The unit is supplied with danger-
During operation, there is a hazard of contact
with dangerous voltage of up to 100 V at the
speaker connections (13). Switch off the ampli-
fier prior to making any changes to the connec-
tions.
= PA-2510D (10 zones)
Please observe the following items in any case:
= PA-2520D (20 zones)
G
The unit is suitable for indoor use only. Protect
it against dripping water and splash water,
high air humidity and heat (admissible ambient
temperature range: 0 – 40 °C).
G
Do not place any vessel with liquid on the unit,
e. g. a drinking glass.
G
The heat generated inside the unit must be
dissipated by air circulation; never cover the
air vents of the housing.
G
Do not operate the unit and immediately dis-
connect the mains plug from the socket
1. if the unit or the mains cable is visibly dam-
2. if a defect might have occurred after the unit
3. if malfunctions occur.
In any case the unit must be repaired by skilled
personnel.
G
Never pull the mains cable to disconnect the
mains plug from the socket, always seize the
plug.
G
For cleaning only use a dry, soft cloth; never
use water or chemicals.
G
No guarantee claims for the unit and no liabil-
ity for any resulting personal damage or mate-
rial damage will be accepted if the unit is used
for other purposes than originally intended, if it
is not correctly connected or operated, or if it is
not repaired in an expert way.
ous mains voltage. Leave servic-
ing to skilled personnel and do not
insert anything into the air vents.
Inexpert handling or modification
may result in electric shock.
aged,
was dropped or suffered a similar accident,
If the unit is to be put out of operation
definitively, take it to a local recycling
plant for a disposal which is not harmful
to the environment.
GB
.
11

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pa-2500rcPa-4300ptt bPa-2520d

Inhaltsverzeichnis