INSTALLATION
SAFETY
7.
Safety
Only qualified contractors should carry out the maintenance and
repair of this appliance.
7.1
General safety instructions
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
DANGER Electrocution
If you mount the appliance on the wall, do so in such
a way that control equipment cannot be touched by a
person in the bath or shower.
CAUTION
!
— Only fit the wall mounted appliance to a vertical
wall that is temperature-resistant to at least 85 °C.
— Observe the minimum clearances to adjacent
object surfaces.
— Never install the appliance directly below a wall
socket.
— Ensure that the power cable is not in contact with
any appliance components.
7.2
Instructions, standards and regulations
Observe all applicable national and regional regulations
and instructions.
Observe the Building and Garage Regulations [or local
regulations].
8.
Appliance description
8.1
Standard delivery
— Wall mounting bracket (hooked into the appliance)
— Feet
— One-way Screws
WWW.STIEBEL-ELTRON.COM
9.
Installation
9.1
Minimum clearances
≥100
9.2
Installation with wall mounting bracket
9.2.1 Installing the wall mounting bracket
You can also use the wall mounting bracket as a template for wall
mounting; this ensures the required floor clearance.
Unhook the wall mounting bracket.
»
Place the centred wall mounting bracket level on the ground and
»
mark holes 1 and 2.
Lift up the wall mounting bracket so that its lower holes match
»
up with the markings you have just made on the installation wall.
Mark holes 3 and 4 on the installation wall.
»
1
2
a a a
Drill holes at all four markings. Secure the wall mounting bracket
»
with suitable materials (screws, rawl plugs) depending on the
type of wall. With the vertical slots, you can compensate for an
offset fixing hole.
≥100
≥500
≥20
3
4
CNS F|