INSTALLATION
TROUBLESHOOTING

9.2.2 Appliance installation

Hook the appliance by its slots in the back of the appliance on
»
to all four tabs of the wall mounting bracket simultaneously.
Push the appliance to latch it in position.
»
Turn the locking bolt in the wall mounting bracket fully clockwise;
»
this locks the appliance in place.
Push the safety cap onto the locking bolt to prevent it from
»
loosening.
1 Locking bolt
2 Wall mounting bracket
1
1 Appliance
2 Safety cap
3 Locking bolt

9.2.3 Dismounting the appliance

Remove the safety cap from the locking bolt.
»
1
1 Appliance
2 Safety cap
3 Locking bolt
Undo the locking bolt on the wall mounting bracket.
»
Lift the appliance up slightly and pull it forwards and away from
»
the wall mounting bracket.
18
|CNS F
9.3
»
»
»
1
2
2
3
9.4
»
»
2
3

10. Troubleshooting

The power cable must only be replaced by a contractor using our
original spare parts.

11. Appliance handover

Explain the functions of the appliance to the user. Draw special
attention to the safety information. Hand the operating and
installation instructions to the user.

Installation with feet

Unhook the wall mounting bracket.
Only remove both external left and right screws at the bottom
of the appliance.
Fit the feet to the bottom of the appliance in such a way that
they are inserted into the recess at the back of the appliance.
Secure the feet with the One-way Screws supplied.

Power supply

Ensure the on-site supply cable has an adequate cross-section.
Ensure that a socket is installed at a distance of at least 10 cm
from the side of the appliance.
DANGER Electrocution!
Carry out all electrical connection and installation
work in accordance with relevant regulations.
DANGER Electrocution!
The appliance must be able to be separated from the
mains power supply by an isolator that disconnects all
poles with at least 3 mm contact separation.
DANGER Electrocution!
Do not install the appliance with a fixed power cable.
Observe the type plate. The specified voltage must
match the mains voltage.
WWW.STIEBEL-ELTRON.COM