Herunterladen Inhalt Inhalt Diese Seite drucken

VOLTCRAFT IR1000-50CAM Bedienungsanleitung Seite 35

Ir-thermometer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

"MAX / MIN"
"AVERAGE
/ DIF"
"AMBIENT
TEMP / % RH"
"DEWPOINT
/ WETBULB"
"TYPE-K"
3.
Aim at the target object, and press and hold the button trigger (7) to measure the temperature at
the target object. According to your setting, the following information will be shown on the display:
Measured by the sensor in the device
AT (ambient temperature)
RH % (ambient humidity)
Calculated information based on the
measurement from the sensor in the
device
DP (dew point temperature)
WB (wet bulb temperature)
Measured by the type-K sensor
TK (Type-K sensor temperature)
The measuring session of the IR sensor will be ended when the button trigger (7) is released. A
new measuring session will be started when you press the button trigger again. That is to say, the
MAX, MIN, AVG and DIF information will be cleared when you press the button trigger (7) again.
The ruler at the bottom of the screen indicates the measuring range of the current measuring
session. The indicator shows the current temperature or the target object.
symbols on screen
The IR measurement is stopped.
34
Enable the display of the values
Select ON to show the respective value on screen during
measurement.
Select OFF to hide the respective value.
Press the button ESC / power (4) to save and go back to the previous
menu.
Measured by the IR temperature sensor
Target point temperature
(in the middle of the screen)
Calculated information based on the
measurement from the IR temperature
sensor
DIF (differential temperature)
MAX (maximum temperature)
MIN (minimum temperature)
AVG (average temperature)
The IR measurement is operating.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis