2.3

Unit configuration

 H
Pump fed
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
32
33
34
 I
Gravity fed
Description
1
Container cover
2
Signal box with level detection device (3) and temperature probe (6)
The signal box is connected to the control system (23, 25)
3
Level detection device
Signals the water level in the filter system
4
Rollers for guiding the filter drum
5
Filter drum with six screen elements
screen elements for coarse dirt down to 80 µm in size (also optionally
available with 60 µm)
6
Temperature probe
monitors the water temperature
7
Air hose 9 mm
8
Hel-X 13 biomedia in moving bed filter chamber
9
DN 110 outlet
10
Meshed tube
Prevents the Hel-X biomedia from being flushed out
11
Aerator rod (two provided)
12
Rinsing pump for supplying the rinsing device (21)
13
DN 75 dirt outlet with slide valve
2 x adapters, 2 x 30° inlet bends with union nut for connection of the Bitron
UVC clarifier to 38 mm (1½ ") connections (16)
Connection set for connecting filter pumps, 1 × 38 mm (1½ ") hose connector,
1 × 50 mm (2 ") hose connector, 1 × union nut for hose connector, 1 × 40 ...
60 mm hose clip, 1 × 90° (2 ") connection bend, 1 × union nut for connection
bend,
1 × flat seal (2 ") 56 mm × 43 mm × 3 mm
2 × 38 mm (1½ ") connection, closed with sealing plugs
optional connection for a Bitron UVC clarifier
1 x 50 mm (2 ") connection for connecting the filter pumps
18
DN 110 dirt outlet for coarse dirt
19
Drum motor for filter drum
the motor is connected to the control system (23, 24)
20
Dirt channel
collects the coarse dirt and rinsing water from the screen elements (5)
21
Rinsing device
sprays water at high pressure onto the screen elements (5) to rinse off the
coarse dirt
22
Grease for the drum seal
23
Control system
24
Connector for drum motor
25
Connector for signal box
26
Power cable
27
Connector for rinsing pump
28
Fuse holder
Fuse protection of the control system with 5 × 20 mm, T8 A 250 V safety
fuse
29
DN 110 inlet
30
DN 110 inlet with cover cap, for optional use
31
2 × ground stakes for installing the control system
32
9/4 mm transition piece
33
Tee
34
2 × cable binders for fastening the air hoses to the tee