To reduce pump noise, connect the pump to the pipework via flexible, pressure-resistant
hose lines for fixed installation.
Equip the suction line with a pre-filter and a non-return or foot valve. In addition, fasten the
suction hose (e.g. tying it to a stake) to take its weight off the pump.
 A
• Install the pump in a horizontal and stable position in a dry place.
– For permanent installation of the pump, ensure that a sufficiently large collecting basin can
be positioned underneath the discharge screw for emptying the pump.
• If possible, install the pump in a higher position than the container/reservoir from which the
water is to be pumped. If this is not possible, a pressure-proof valve must be fitted between
the pump and the suction hose.
• Only use vacuum-proof pressure hoses on the pressure and suction side.
• Screw a suction and pressure hose with 25.0 mm internal diameter (1") onto the connections.

Operation

CAUTION
Risk of burns due to hot water. Water in the pump may be heated to a high temperature in the
event of defective electronics or lack of water supply on the suction side.
Disconnect the power plug before carrying out any work on the unit.
Allow the water in the pump to cool down.

Starting up the unit

It is necessary to fill the pump and expel the air from the suction line before using. It can take
several minutes to expel air from the suction line.
How to proceed:
 B
1. Unscrew the water infill screw.
2. Pour water into the infill opening until it overflows.
3. Screw in the water infill screw again.
4. Open the pressure line if necessary.
5. Insert the power plug into the socket.
6. Switch on the pump.
– The pump starts pumping immediately. The emerging water still contains some air.