Herunterladen Inhalt Inhalt Diese Seite drucken

Ec: Extended Cleaning Time "Extra Cleaning; In: Time-Dependent Cleaning "Interval - Oase ProfiClear Premium Compact Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für ProfiClear Premium Compact:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- EN -
6.5.2

EC: Extended cleaning time "Extra Cleaning"

To prevent larger deposits from building up in the dirt channel or pipework, the unit performs a cleaning
cycle with an extended cleaning time after every 20 cleaning cycles. This ensures that the pipework is
flushed out at regular intervals.
However, if dirt and residue build up due to unfavourable conditions, you can increase the cleaning time
and flush out the pipe with additional water. The default setting for the extended cleaning time is 20 s.
How to proceed
1.
Menu
Press
several times until EC appears in
the display.
2.
Menu
Press
for 5 s until the cleaning time is
indicated in the display.
3.
Menu
Press
several times to change the
value.
To change the value quickly: Hold down the
button.
6.5.3

In: Time-dependent cleaning "Interval"

In addition to automatic cleaning, the unit can also perform a time-dependent cleaning cycle. This is
particularly useful for ponds containing fish because even if there is only a small amount of dirt, excrement
is always removed from the water cycle before it leads to a build-up of nutrients.
Adjust the time interval to meet the requirements. The drum filter module is normally optimally set with a
time interval of 20 minutes (default setting). The function is deactivated with a time setting of 0 minutes.
The time-dependent cleaning cycle does not have any influence on the automatic cleaning cycle that starts
when the water level is too low. After each automatic cleaning cycle, the time interval is reset and starts
again from the beginning.
The time-dependent cleaning cycle also protects the filter system from freezing. For this, please refer to
the information about safe overwintering. ( Storage/overwintering)
Proceed as follows
1.
Menu
Press
several times until In appears in
the display.
2.
Menu
Press
for 5 s until the time is indicated in
the display.
3.
Menu
Press
several times to change the
value.
To change the value quickly: Hold down the
button.
54
Information
To cancel and exit the menu: Either wait for 10 s or press
To cancel and exit the menu: Either wait for 5 s or press
Settable range: 10 – 60 s
Increment: 1 s
The number can only be changed upwards. Once the value 60 is reached,
the display returns to 10.
Saving the set value: Wait for 5 s until the menu is automatically exited.
Cancel without saving and exit the menu: Press
Information
To cancel and exit the menu: Either wait for 10 s or press
To cancel and exit the menu: Either wait for 5 s or press
Settable range: 0.3 – 60 min
0 min: No time-dependent cleaning
Increment: 1 min
The number can only be changed upwards. Once the value 60 is reached,
the display returns to 0.
Saving the set value: Wait for 5 s until the menu is automatically exited.
Cancel without saving and exit the menu:
On|Off
Clean
or
.
On|Off
Clean
or
.
On|Off
Clean
or
.
On|Off
Clean
or
.
On|Off
Clean
or
.
On|Off
Clean
or press
.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis