Herunterladen Inhalt Inhalt Diese Seite drucken

Oase ProfiClear Premium Compact Gebrauchsanweisung Seite 50

Vorschau ausblenden Andere Handbücher für ProfiClear Premium Compact:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- EN -
Filter drum
5. Manually turn the filter drum for one whole rotation to ensure unobstructed movement.
6. Fill the filter with water until the rinsing pump is submerged (dry run protection of the rinsing pump).
7. Fit the container cover.
Control system and remaining units, pipes
8. Switch on the control system and perform any necessary adjustments. (→ Operation)
9. Switch on the filter pump and UVC clarifier (if applicable).
Ensure that the water is returned to the pond via the return pipe.
10. Check all pipes, hoses and their connections for leaks.
Expansion seals may leak initially until they have fully expanded on contact with water.
11. Adjust the level detection device, if necessary. (→ Adjusting the level detection device)
When using filter starter, medicines or pond water treatments, leave the UVC clarifying unit switched off
for at least 36 hours so as not to impair their efficacy.
Gravity fed system
 I
How to proceed:
1. Close the slide valve for the dirt outlet at the bottom of the container.
2. Check that the entire filter system (pipes and hoses) is complete.
3. Remove the container cover.
The filter drum is stopped for safety reasons if the filter cover is lifted and Er11 is indicated in the
display of the control system.
Moving bed filter chamber
The moving bed filter chamber contains two 20 l sacks of Hel-X 13 biomedia (40 l). Optionally, 60 l can be
used (supplementary kit Order No.: 42904).
4. Tip the Hel-X biomedia from the bags into the moving bed filter chamber.
Ensure that the Hel-X biomedia can move around freely in the container.
It can take several weeks for the Hel-X biomedia to become completely colonised. Uncolonised Hex-
X biomedia tend to float more.
When using the supplementary kit, add the biomedia gradually. We recommend adding max. 5 l per
week.
2222555555
Filter drum
5. Manually turn the filter drum for one whole rotation to ensure unobstructed movement.
6. Fill the filter with water until the rinsing pump is submerged (dry run protection of the rinsing pump).
7. Open the slide valve at the inlet and outlet, if applicable, to fill the filter system with water.
8. Fill the pond until the maximum water level is reached.
9. Check the water level in the drum filter module. Refer to the sticker with level markings on the inside
wall of the container.
Ideal water level: 90 mm below the top edge of the container
Permissible tolerance: -20 mm (110 mm below the top edge of the container)
Correct the installation if the minimum water level is not reached.
10. Fit the container cover.