Adjust cleaning temperature
Set device switch to desired tempera-
ture.
Set working pressure and flow rate
Pressure/quantity regulation of the
pump unit
Turn the regulation spindle in a clock-
wise direction: Increase working pres-
sure (MAX).
Turn the regulation spindle in an anti-
clockwise direction: Reduce working
pressure (MIN).
Cleaning
Set pressure/temperature according to
the surface to be cleaned.
Note: To prevent damage due to too much
pressure, always position high pressure ray
first from a greater distance towards object
to be cleaned.
Operating with cold water
Removal of light contaminations and clear
rinse, i.e.: Gardening tools, terrace, tools,
etc.
Set operating pressure according to
need.
Eco level
The appliance works in the most economi-
cal temperature range (max. 60 °C).
Operating with hot water
DANGER
Scalding danger!
Set device switch to desired tempera-
ture.
We recommend the following cleaning tem-
peratures:
– Light contaminations
30-50 °C
– Contaminations containing protein, i.e.
in the food processing industry
max. 60 °C
Interrupting operation
Secure the trigger gun. To do so, push
the safety catch towards the front.
Turn off the appliance
DANGER
Danger of scalding from hot water! After op-
eration with hot water, the device must be
operated with openend handgun with cold
water for at least two minutes.
Shut off water supply.
Open the hand spray gun.
Switch on the pump with the power
switch and allow to run for about 5-10
seconds.
Close the hand spray gun.
Set the appliance switch to "0/OFF".
Pull main plug out of socket with dry
hands only.
Remove water connection.
Activate hand spray gun until device is
pressure less.
Secure the trigger gun. To do so, push
the safety catch towards the front.
Storing the Appliance
Lock in the steel pipe into the holder of
the appliance hood.
Roll up high pressure hose and electri-
cal conduit and hang them into the re-
spective holders.
Note: Do not twist high pressure hose and
electrical conduit.
Frost protection
ATTENTION
Risk of damage! Frost will destroy the appli-
ance if the water has not been completely
drained.
Store in a frost free area.
If the device is connected to a chimney, the
following must be observed:
ATTENTION
Threat of damage by penetrating cold air
through the chimney.
– 6
EN
23