pH value
electrical conductivity *
settleable solids **
total suspended solids *** < 50 mg/l
Hydrocarbons
Chloride
Sulphate
Calcium
Total hardness
Iron
Manganese
Copper
Active chloride
free of bad odours
* Maximum total 2000 µS/cm
** Test volume 1 l, settling time 30 min
*** no abrasive substances

Safety instructions

– Please follow the national rules and
regulations for fluid spray jets of the re-
spective country.
– Please follow the national rules and
regulations for accident prevention of
the respective country. Fluid spray jets
must be tested regularly and the results
of these tests must be documented in
writing.
– The heating appliance of the machine is
an ignition plant. All national laws and
regulations about heating systems must
also be followed.
– The appliance/accessories must not be
modified.

Safety Devices

Safety devices serve for the protection of
the user and must not be put out of opera-
tion or bypassed with respect to their func-
tion.
20
6,5...9,5
Conductivity
fresh water
+1200 µS/cm
< 0,5 mg/l
< 20 mg/l
< 300 mg/l
< 240 mg/l
< 200 mg/l
< 28 °dH
< 50 °TH
< 500 ppm (mg
CaCO
/l)
3
< 0,5 mg/l
< 0,05 mg/l
< 2 mg/l
< 0,3 mg/l
EN
Overflow valve with two pressure
switches
– When the water supply at the pump
head is reduced, the overflow valve
opens and part of the water flows back
to the suction side of the pump.
– If the hand-spray gun is closed, so that
the whole water flows back to the pump
suck side, the pressure switch at the
overflow valve shuts down the pump.
– If the hand spray gun is opened, the
pressure switch on the cylinder head
turns the pump back on.
The overflow valve is set by the manufac-
turer and sealed. Setting only by customer
service.
Safety valve
– The safety valve opens, when the over-
flow valve resp. the pressure switch is
broken.
The safety valve is set by the manufacturer
and sealed. Setting only by customer service.
Water shortage safeguard
– The water shortage safeguard prevents
the burner to be turned on when there is
water shortage.
– A sieve prevents the contamination of
the safeguard and must be cleaned reg-
ular.
Temperature stop for exhaust gases
– The temperature stop switches off the
machine when the waste gases have
reached very high temperatures.

Start up

WARNING
Risk of injury! Appliance, accessories, sup-
ply lines and connections must be in fault-
free condition. If they are not in a perfect
state then the appliance must not be used.
 Lock parking brake.
Installing the handle
Figure 3
Screw tightening torque: 6.5-7.0 Nm