O P E R A T I N G I N S T R U C T I O N S
2.3
Correct use
The UE43 xAR safety relays must be used only as
UE43-3AR/UE43-4AR
defined in section 2.2 "Applications of the device".
They may only be used by qualified safety person-
nel and only on the machine where they have been
Safety relay
installed and initialised by qualified safety person-
nel in accordance with the operating instructions.
If the device is used for any other purposes or
en
modified in any way — also during mounting and
installation — any warranty claim against SICKAG
shall become void.
SICK AG • Industrial Safety Systems
Erwin Sick-Straße 1
The modules can be used in lift applications.
D-79183 Waldkirch • www.sick.com
2.4
General safety notes and protective
8012209/YSS6/2016-03-17 • REIPA/XX
Printed in Germany (2016-03) • All rights
measures
reserved • Subject to change without notice
Pay attention to the safety notes and
protective measures!
Please observe the following items in order
to ensure correct use of the UE43 xAR
safety relays.
During the mounting, installation and usage of
the safety relays, observe the standards and
directives applicable in your country.
The national/international rules and regulations
1
Scope
apply to the installation, commissioning, use and
These operating instructions are only applica-
periodic technical inspection of the safety relays,
ble to the UE43 xAR safety relays with the
in particular:
following entry on the type label in the field
– Machinery Directive
Operating Instructions: 8012209
– Work Equipment Directive
You will find the device's date of manufacture
– EMC directive
on the type label in the field Date Code in the
format yywwxxxx (yy = year, ww = calender
– the work safety regulations and safety rules
week, xxxx = serial number).
Manufacturers and operators of the machine on
These operating instructions are original
which a safety relay is used are responsible for
operating instructions.
obtaining and observing all applicable safety
regulations and rules.
2
On safety
The tests must be carried out by qualified safety
personnel or specially qualified and authorised
2.1
Qualified safety personnel
personnel and must be recorded and documen-
The UE43 xAR safety relays must only be
ted to ensure that the tests can be reproduced
mounted, installed, commissioned and
and retraced at any time by third parties.
checked by qualified safety personnel.
The operating instructions must be made avai-
Qualified safety personnel are defined as
lable to the operator of the machine where a
persons who ...
safety relay is used. The machine operator is to
be instructed in the use of the device by quali-
have undergone the appropriate technical
fied safety personnel and must be instructed to
training and
read the operating instructions.
have been instructed by the responsible
The safety relay complies with class A, group 1
machine operator in the operation of the
as per EN 55 011. The Group 1 encompasses all
machine and the current valid safety
ISM devices in which intentionally generated
guidelines and
and/or used conductor-bound RF energy that is
have access to the operating instructions of
required for the inner function of the device
the UE43 xAR safety relay and have read
itself occurs.
and familiarised themselves with them.
2.5
Environmental protection
2.2
Applications of the device
Disposal of unusable or irreparable devices must
The UE43 xAR safety relays can be used
always occur in accordance with the applicable
in accordance with EN ISO 13 849-1 up to
country-specific waste-disposal regulations (e.g.
PL e and category 4
European Waste Code 16 02 14).
in accordance with EN 62 061 to SILCL3
The category actually attained depends on the
external circuit, the design of the wiring, the
selection of the control switches and their
placement on the machine.
The UE43 xAR safety relay has been evaluated
to UL 508.
Tactile safety sensors (e.g. safety switches,
emergency stop pushbuttons) are connected
to the safety relays. The corresponding actu-
ators of the machines or systems can be
switched off safely via the switching outputs
of the safety relays.
3
Product description
5
The inputs on the UE43 xAR are prepared for the
Switch the entire machine/system off
connection of the control switches or safety sen-
line!
sors listed in section 2.2 "Applications of the
The system can start up unexpectedly while
device".
you are connecting the devices.
The following devices can be connected to the
UE43 xAR:
The voltage supply must satisfy the regulations
emergency stop pushbuttons (EN ISO 13 850):
for extra-low voltages with safe isolation (SELV,
single- or dual-channel,
PELV) for overvoltage category III as per
safety switches (EN 1088): single- or dual-
EN 60 664 and EN 50 178.
channel.
For installation in environments with overvoltage
category III, external protection elements must
In order to attain SIL3/PL e, connect the
be used. The required level of protection as per
external device monitoring!
EN 62 305-1 can be achieved using an external
In order to reach SIL3/PL e, an external
snubber circuit. The protection elements (SPD –
diagnosis with DC K 99 % must be applied
surge protective devices) must comply with the
(i.e. the external device monitoring must be
requirements as per EN 61 643-11.
connected).
The insulation on the cables as well as the
Please also read the notes in chapter 11
equipment connected (switches, sensors, valves
"Application examples".
etc.) are to be designed for the highest voltage
occurring in the device.
The maximum cable length L
3.1
Status indicators
connection of the input circuit is calculated
using the formula L
Display
Meaning
metre cable.
PWR
Green
Supply voltage active
Lay the cables for a reset button connected with
K1
Green
Channel 1 switched
protection, e.g. in separate plastic-sheathed
cables, to the inputs S12, S22, S52.
K2
Green
Channel 2 switched
All connections, wiring and cable runs must
3.2
Pin assignments
comply with the required category as per
EN ISO 13 849-1 and the required SIL claim
Assignment
Description
level as per EN 62 061 (e.g. cables laid with
A1
Voltage supply (+ 24 V DC)
protection, individually sheathed cable with
A2
Voltage supply (0 V DC)
screen etc.).
In order to protect the safety outputs and to
S11
+ Control voltage
increase the service time of the module, all
S21
0 V control voltage
external loads must be equipped with e.g.
S12
+ Input circuit 1 (K1)
varistors and RC circuits. Please also note that
the selection of the arc suppression can
S52
+ Input circuit 2 (K2)
increase the total response time of the safety
S22
– Input circuit 2 (K2)
function.
S11–S34
Reset
The output signal switching devices, the connec-
13/14
Enable current path 1
tion between S11 and S34 and the external
device monitoring (EDM) must be wired in the
23/24
Enable current path 2
control cabinet.
33/34
Enable current path 3
To prevent the welding of the contacts on the
43/44
Enable current path 4
built-in relay, an overcurrent protection device
Only in UE43-4AR variants
with short-circuit protection (duty class gG) in
accordance with the related usage category is to
41/42
Signalling current path (not safe)
be selected and integrated into the enable
Only in UE43-3AR variants
current paths.
4
Mounting
5.1
Single-channel operation
Mounting only with enclosure rating IP 54
The volt-free switching element on the safety
or better!
sensor is to be connected between S11 and S12.
The UE43 xAR is only suitable for mounting
Wire jumpers are to be connected between S12
in a control cabinet with at least IP 54
and S52 as well as between S21 and S22.
enclosure rating.
Dual-channel operation
The modules are located in a 22.5 mm wide
The two volt-free switching elements on the safety
modular system for 35 mm DIN rails as per
sensor are to be connected between S11 and S12
EN 60 715.
or S21 and S22. A wire jumper is to be connected
Mounting in accordance with EN 50 274.
between S11 and S52.
5.2
A wire jumper is to be connected between S11 and
S34.
5.3
The EDM contacts are to be connected between
S11 and S34. EDM contacts replace the wire
jumpers.
Electrical installation
6
Commissioning and regular
tests
Commissioning requires a thorough check
by qualified safety personnel!
Before the initial commissioning of the
system in which you are using a UE43 xAR
safety relay, it must be checked and
released documented by qualified safety
personnel.
Check the hazardous area!
You must ensure that no one is located in
the hazardous area before commissioning.
Control the hazardous area and secure it
against entry. Observe the relevant laws
and local regulations.
6.1
Regular inspection of the
protective devices by qualified
safety personnel
for the
max
Check the system following the inspection
intervals specified in the national rules and
= 60 Ohm/resistance per
max
regulations. This procedure ensures that any
changes on the machine or manipulations of the
protective device after the initial commissioning
are detected.
The safety relays must be cyclically
tested!
In order to reach the required safety level
(see "Technical specifications"), the follo-
wing test must be performed at least every
365 days:
The UE43 xAR must be powered down.
The UE43 xAR must be powered up.
All safety functions of the connected
equipment must be verified.
Have the application in which the safety relays
are used checked at regular intervals by quali-
fied safety personnel or appropriately authorised
personnel. The effectiveness of the protective
devices must be checked daily by a specialist or
by authorised personnel.
If changes have been made to the machine or
the protective device, or the safety relay has
been changed or repaired, you must again
thoroughly check the entire safety application.
7
Diagnostics
Input circuit
7.1
In the event of faults or errors
Cease operation if the cause of the mal-
function has not been clearly identified!
Stop the machine if you cannot clearly
identify or allocate the error and if you
cannot safely rectify the malfunction.
Complete function test after rectification
of fault!
After rectifying a fault, perform a complete
function test.
Reset
External device monitoring (EDM)
8
Ordering information
3/1 R
R
UE43-3AR2D2 6034565
3/1 R
R
UE43-3AR3D2 6034568
4/0 R
R
UE43-4AR2D2 6034772
4/0 R
R
UE43-4AR3D2 6034775
9
Compliance with EU
directives
EU declaration of conformity (excerpt)
The undersigned, representing the following
manufacturer herewith declares that the pro-
duct is in conformity with the provisions of the
following EU directive(s) (including all applica-
ble amendments), and that the respective
standards and/or technical specifications are
taken as the basis.
Complete EU declaration of conformity for
download: www.sick.com

Werbung

loading

Diese Anleitung auch für:

Ue43-4ar