Fault
Cause, measure
Fan does not
No mains voltage.
switch on.
Check whether the mains
fuse has failed. Switch on
if necessary.
If necessary, also check
the service switch.
Motor's
Motor too hot.
thermal
Leave the unit switched off
overload
until the motor and the
protection
temperature limiter cool
switches the
down. It may takeup to
30 minutes to cool down.
fan off.
Only then, switch the unit
back on.
Impeller is blocked.
Fan does not
Repairs may only be
switch on.
carried out by a trained
specialist: Check impeller
and clean if necessary.
Deposits on the
Call on the services of a
impeller and in
trained electrician. Install an
the housing
air filter in the duct system.
caused by dust
Under no circumstances
in the air.
should the inside of the unit
be cleaned with water or a
high-pressure cleaner.
Impeller not
Switch off unit. Ensure that
turning.
the impeller is not blocked
by foreign bodies.
If the fault still continues or occurs
again, disconnect the fan from the
power supply at all poles.
Let a certified electrician determine
the cause of the fault and eliminate it.

10. Spare parts

Spare parts may only be sourced
from and fitted by a specialist
installer.
Item
Spare parts available
9
Motor
11
Impeller
20
Capacitor
9. Fault rectification │ uk
When ordering spare parts, please provide
the following details:
1. Print no. of these instructions
0185.1171.0000.
2. Rating plate no., on side of rating plate
( unit,  instructions envelope)
3. Item number
Should you have any questions
Maico Elektroapparate-Fabrik GmbH
Steinbeisstrasse 20
78056 Villingen-Schwenningen, Germany
Tel. +49 (0)7720 694445
Fax +49 (0)7720 694175
E-mail: ersatzteileservice@maico.de

11. Dismantling

Dismantling may only be undertaken
by a trained electrician ( Chapter 1).
Danger to life from electric
shock.
Prior to access to the connection
DANGER
terminals switch off all supply
circuits. Switch off mains fuse,
secure against being accidentally
switched back on and position a
visible warning sign.
1. Switch off mains fuse, secure and fit
warning sign.
2. Remove connection components from fan.
3. Remove the terminal box cover.
4. Remove all cables.
5. Remove fan.

12. Disposal

Do not dispose of in domestic
waste. The unit contains in part
materials that can be recycled and in
part substances that should not end
up in the domestic waste.
Dispose of the unit once it has reachedthe
end of its service life according to the
regulations valid in your country.