UK │ 12. Fault rectification
Fan does
No mains voltage.
Check whether the mains fuse
not
has failed. Switch on if
switch
necessary.
on.
Impeller blocked.
Fan does
Should only be carried out by a
not switch
trained electrician: Unlock and
on.
remove the internal grille/ shutter
frame [12] ( Fig. D). Check
impel-ler and clean if necessary.
Fan does
VZ or F units: Wait for overrun
not switch
time (approx. 6 minutes).
off.
Motor's
Motor too hot. Wait until
thermal
the motor has cooled. Cool-down
overload
time can be up to 10 minutes. Unit
protection
switches back on automatically
switches
after cooling.
the fan
off.
Lamella
Lamella very dirty or blocked.
do not
Clean lamella.
open or
Check whether there is any-thing
between the lamella. Remove if
close for
necessary.
K units.

13. Spare parts

Spare parts may only be sourced from
and fitted by a specialist installer.
Item
Designation
5.1
Mother board:
Standard device
types, 24-V, K
5.2
VZ circuit board:
VZ + KVZ
device types
5.3
F circuit board:
F + KF device
types
10
ECA 120 K:
Thermostatic
bimetal strip
12
ECA 120:
internal grille
ECA 120 K:
Shutter frame
16
Article no.
F101.1010.9000
0101.1257.0000
0101.1255.0000
E180.0913.9100
0059.1010.9000
0059.1011.9001
In the case of questions:
Maico Elektroapparate-Fabrik GmbH
Steinbeisstraße 20
78056 Villingen-Schwenningen, Germany
Tel. +49 7720 694 445 / Fax +49 7720 694 175
e-mail: ersatzteilservice@maico.de

14. Dismantling

Dismantling should only be carried out by
a trained electrician.
1. Before dismantling, disconnect the unit at
all poles from the power supply (switch off
mains fuse), secure against being
accidentally switched back on and fit a
visible warning sign.
CAUTION
Danger of burning due to contact with
bimetal [10] (K units). Bimetal is very hot
after fan is switched off. Do not touch. Cool-
down time can be up to 10 minutes.
2. Unlock and remove the internal
grille/shutter frame [12] ( Fig. D).
3. Remove electronics cover [7], remove
power cable.
4. Remove fan. To do this, press both locking
hooks [1] out of their latched positions
using a screwdriver and pull the fan out
by pulling with equal force on both sides.
15. Environmentally responsible
disposal
The unit and the packaging contain parts that
can be recycled, and should not end up in the
domestic waste. Dispose of the packaging
material in an environmentally-friendly way,
in compliance with the regulations valid in the
country where you are. At the end of its
service life, dispose of the unit in an
environmentally-friendly way, in compliance
with the regulations valid in the country where
you are.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Eca 120

Inhaltsverzeichnis