Please observe that the charging output of the charger is max. 50 W. A charging current
of 5 A is only reached up to a charging voltage of approx. 10 V.
If a higher charging voltage is needed, the charging current will reduce automatically
according to the maximum output.
• Connect the connection cable of the balancer adapter plate (13) to the balancer connection
(6) of the charger.
• Connect the balancer connection of the rechargeable battery (14) to the balancer adapter
plate. Use the socket matching the cell number for this.
The plug system used at the charger is designated „XH". If other plug connectors
(EH, HP/PQ or TP/FP) are connected to your rechargeable batteries, the matching
adapters from accessories trade must be used.
• Connect the mains cable to the mains socket (2) and plug the mains plug into a mains
socket.
• Directly after connection to the mains, the 6 LEDs of the balancer display (3) and the
charger conditions display (5) will light up briefly. Then LEDs 1 - 6 of the balancer display will
light up briefly, depending on the number of cells of the connected rechargeable battery.
If the rechargeable battery is connected correctly, charging commences.
According to the cell number, the LEDs of the balancer display and the charger condition
display remain lit red.
• When starting charging, the charger condition display lights up red to signal the current-
controlled charge condition („Constant Current" mode). For this, the charging voltage is
continually increased to maintain the set charging current constant.