2 Attention messages and alarms

XP AIR draws the diver's attention to certain situations and warns the diver of unsafe diving practices.
Attention messages and alarms are always visual and audible under water, only visual at the surface
except the decompression alarm.
F
The audible attention messages (but not the alarms) can be selectively switched off with
Dive.Log.

2.1 Attention messages

Attention
messages
to the diver visually by symbols, letters or
flashing figures. In addition, two short audible
sequences can be heard (in an interval of 4
seconds) in two different frequencies under
water.
4sec
(can be switched off)
Attention messages come up in the following
situations (more information can be found on
the listed pages):
Maximum Operating Depth / max
ppO
is reached
2
Set maximum depth is reached
Oxygen toxicity reaches 75%
No-stop time = 2 minutes
Prohibited altitude* (surface mode)
Entering decompression when diving
with L0
Remaining Bottom Time < 3 minutes
Tank pressure has reached set warning
level
Increased workload
Diving with microbubble levels (l1-l5):
MB no-stop time = 0
MB level stop ignored
MB level reduced
Entering decompression when diving
with MB level L1-L5
*without audible attention beep
! WARNING

2.2 Alarms

are
communicated
Serious injury or death may result from failing
to immediately respond to alarms given by
XP AIR.
Alarms are given to the diver visually by
flashing symbols, letters or figures. In addition,
an audible sequence in one frequency can be
heard during the whole duration of the alarm.
off)
An alarm occurs in the following situations
(more information can be found on the listed
Page
pages):
21
19
21
23
26
24
22
low battery alarm XP AiR**
22
22
31
32
32
Transmitter battery low: **
32
"bAt" flashing and alternating with the display
of the tank pressure.
**without audible alarm
(can not be switched
Oxygen toxicity reaches 100%
Ignored decompression
Remaining Bottom Time = 0
Exceeding the prescribed ascent rate 20
(Particular scale of beeps, ->20)
Low battery alarm**
The
appears if the battery
capacity reaches 0%.
Take the unit to your
authorised
retailer.
Replace the battery in
the transmitter ->38.