About the device

1.

Introduction

The laboratory power supplies of the series PS 8000 2U are
ideally suited for test systems and industrial control facilities by
their 19" draw-out case.
Apart from standard functions of power supplies the user can
define and recall 5 different presets of set values or make use of
the integrated analogue interface, that can handle the common
voltage ranges of 0...5V or 0...10V. This offers a way of easily
monitoring the device as well as total remote control.
The optionally available, digital interface cards provide an even
wider spectrum of control and monitoring functions by means
of a PC.
Models from 1000W feature an adjustable power regulation
circuit (with two exceptions, see technical specs), as well as
a „System Bus" terminal which enables series connection as
master-slave or parallel connection with share bus.
The integration into existent systems is done very comfortably
by using an interface card, while there is no need to configure
the card at all or with only a few settings.
Via the analogue interface, a power supply can als be operated
in connection to other power supply units, controlling these via
the interface. Or they can be controlled and monitored by an
external control system, like a PLC.
The devices are microprocessor-controlled and thus delivers
fast and accurate measurement and indication of actual values.
The main functions at a glance:
• Set voltage and current, each with 0...100%
• Adjustable overvoltage threshold 0...110% U
• Pluggable interface cards (CAN, USB, RS232, IEEE/GPIB,
Ethernet/LAN, Profibus)
• Analogue interface for external control and monitoring with
0...5V or 0...10V (selectable) for 0...100%
• Power ratings of 640W, 1000W, 1500W and 3000W
• Temperature controlled fan
• Status indication (OT, OVP, CC, CV, CP)
• 5 selectable memory sets
• Series connection (models from 1kW, except the 720V model)
• Share-Bus for parallel operation (models from 1kW)
• Vector™ compatible CAN system
• Free Windows software
• LabView™ VIs
Instruction Manual
PS 8000 2U Series
2.

Technical specifications

2.1

Control panel and display

Type
Display:
Knobs:
Display formats
The nominal values define the maximum adjustable range.
Actual values of voltage and current are displayed simultane-
ously, the set values of the overvoltage threshold, the under-
voltage limit, voltage, current and power (models from 1kW)
are displayed seperately.
Display of voltage values
Resolution:
Formats:
Display of current values
Resolution:
Formats:
Nom
Display of power values (models from 1kW)
Resolution:
Formats:
Dot matrix display 202 x 32 dots,
seperated into three areas
2 rotary knobs, 9+2 pushbuttons
4 digits
0.00V...99.99V
0.0V...999.9V
4 digits
0.000A...9.999A
0.00A...99.9A
0.0A...999.9A
4 digits
0.000kW...9.999kW