Maintenance

Defective door systems and safety equipment
result in the risk of injury.
For your safety, you should comply with the
recommended maintenance intervals for your
door system, including all safety equipment.
Maintenance interval:
Have the door system inspected by a specialist
company before initial operation and then as
required, but at least once a year.
Regular checks of wearing parts:
There is a risk of injury due to defective or
worn components.
Check the system therefore regularly for signs of wear,
damage or lack of balance of the door.
Do not use the door under any circumstances if repairs
or adjustments need to be made, as a faulty or imbal-
anced door can lead to injuries.

Monthly checks on the obstacle recognition (power limiting)

1.
Run the door into the nal open position.
2.
Place a 50 mm high object, e. g. a wooden
block, in the direction of travel of the door.
3.
Close the door by actuating the hand trans-
mitter.
4.
If the door hits an obstruction when closing or
opening, the door opener automatically stops
and opens the garage door fully.
5.
After this, remove the obstruction.
6.
After removing the obstruction, you can oper-
ate the garage door opener normally again.
Check:
All screw connections to ensure they are tight
Cables for damage
Springs and xing parts
There is a risk of injury due to the extremely
taut door springs.
Never replace the door springs yourself.
Have all work on the mechanical system and
springs carried out by a quali ed person.
Placing an approx. 50 mm wooden block in the
direction of travel of the door.
If necessary, correct and check the alignment
once again, as an incorrect alignment cause
pose a threat.
EN