Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 3
Hold the spray gun in a suitable
N
empty receptacle (> 20 l) and
actuate for exactly 1 minute
Read the detergent consumption
N
"QR" on the scale
Calculating the actual detergent
concentration:
QR
x V = concentration
Q
QR = amount of consumed
detergent (in l/min)
Q = Water without detergent
(in l/min)
V = Predilution of detergent (in %)
If the actual concentration deviates from
the desired concentration, reset knob
and repeat measurement if necessary.
Calculating the predilution of the
detergent in %
If the predilution is not indicated as a
percentage, it can be calculated using
the following table:
Ratio
1:1
=
50 %
1:2
=
33.3 %
1:3
=
25 %
1:5
=
16.6 %
1:10
=
9 %
Example:
Calculation ratio of 1:2
A = 1
B = 2
RE 661, RE 661 PLUS, RE 961 PLUS
A
x 100 = value in %
(A + B)
1
x 100 = 33.3 %
(1 + 2)

Steam cleaning mode

Open the side cover – see "Open
N
shroud"
Turn the knob on the pressure and
N
flow control counter-clockwise as
far as possible
Turn the master switch to uv
N
Set the knob to the desired
N
temperature (above 100 °C or
212 °F respectively)
Use the steam nozzle for professional
steam cleaning and special applications
– see "Special accessories".
English
53

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Re 961

Inhaltsverzeichnis