INSTALLATION

Installing/Replacing the lamp

For the installation, you need one of the following lamps:
OMNILUX OSD 5 Reflector 200W discharge lamp
MSD Platinum 5R discharge lamp
The lamp must only be changed when wearing appropriate protective clothing (protection glasses, protection
gloves, helmet with sight, leather apron).
The lamp life given by the manufacturer must never be exceeded. This is why you need to take notes on the
operational time of the lamp or check the operating hour meter (if available) regularly and replace the lamp in
time.
Keep exchanged lamp in a protective container and remove accordingly.
During the operation, the lamp reaches temperatures of up to 600° C.
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 15 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
Because of the nature of the extreme heat associated with the 5R discharge lamp and the tight nature
of the internal optical system it is imperative that the lamp be replaced every 2000 hours. This is
done to protect the internal optical system as well as prevent accidental lamp explosion, which could
lead to hot glass particles falling from the fixture.
Procedure:
Step 1: Unscrew the fixation screws A, B, C, D of the lamp system and carefully
remove it from the housing.
Step 2: If replacing the lamp, remove the old lamp. First of all, carefully remove
the two blade terminals from the lamp base.
Step 3: Carefully insert the new lamp into the lamp holder until it snaps in.
Carefully attach the two connection wires onto the lamp base.
Step 4: Replace the lamp system cover and tighten the fixation screws.
Attention: Please note, the 5R lamp is not a hot-restrike type. You must wait
approximately 15 minutes before you can attempt to strike the lamp once it has been turned off!

DANGER TO LIFE!

Only install the lamp with the device switched off!
Unplug from mains before!
CAUTION!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
Do not operate this device with opened cover!