3.9.

Locating the connection box for connection cable in the sauna room

A = Specified minimum safety clearance
1. Recommended location for the connection box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connection
box must be clear of obstacles. When installing the connection box to zones 2 or 3, refer to the
instructions and regulations of the local energy supplier.
A
KIUAS
Image 3. Location for the connection box
A
3.
1.
2.
24