Sauna heater insulation resistance: The sauna heater heating elements may absorb moisture from air, e.g.
during storage. This may cause bleeder currents. The moisture will be gone after a few heating sessions.
Do not connect the heater power supply through a ground fault interrupter.
However, adhere to the effective electrical safety regulation when installing the sauna heater.
Table 2. Mains connection:
Output
Heater connection
cable H07RN-F /
60245 IEC 66
400 – 415V 3N~
mm
kW
6,3
5 x 1.5
8,0
5 x 2.5
9,0
5 x 2.5

3.5. Block diagram of the electric and HPAC connections

OLET 21
Fuse
Heater connection
cable H07RN-F /
2
A
3 x 10
3 x 16
3 x 16
OLET 19
Fuse
60245 IEC 66
230V 3~
2
mm
4 x 2.5
3 x 16
4 x 6
3 x 25
4 x 6
3 x 25
1
2
3
4
Heater water connection 1/2" *
Heater connection
cable H07RN-F /
60245 IEC 66
230–240V 1N~/2~
2
mm
A
3 x 6
3 x 6
-
A
R
A
OK
Voltage to the heater 400V 3N~
Fuse
A
35
35
-
)
21