Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data - Siemens SIMOVERT MASTERDRIVES Betriebsanleitung

Vorschau ausblenden Andere Handbücher für SIMOVERT MASTERDRIVES:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

SLB - SIMOLINK Board
2

Technical Data

Order number
Size (length x width)
Degree of pollution
Mechanical strength
During stationary duty
- Deflection
- Acceleration
During transport
- Deflection
- Acceleration
Climate class
Type of cooling
Permissible ambient or coolant
temperature
- During operation
- During storage
- During transport
Siemens AG 6SE7087-6NX84-0FJ0
SIMOVERT MASTERDRIVES
08.2000
6SE7090-0XX84-0FJ0
90 mm x 83 mm
Pollution degree 2 according to IEC 644-1(DIN VDE 0110/T1,
moisture condensation is not permissible in operation
According to DIN IEC 68-2-6 (for correctly installed board)
0.15 mm in frequency range 10 Hz to 58 Hz
19.6 m/s² in frequency range > 58 Hz to 500 Hz
3.5 mm in frequency range 5 Hz to 9 Hz
9.8 m/s² in frequency range > 9 Hz to 500 Hz
Class 3K3 according to DIN IEC 721-3-3 (in operation)
Natural-air cooling
0° C to +70° C (32° F to 158° F)
-25° C to +70° C (-13° F to 158° F)
-25° C to +70° C (-13° F to 158° F)