- A PNP transistor is in working order if the LED starts blinking as
soon as the test tip on the base is touched while at the same time
tapping the emitter or the collector with the finger.
Microwave Leak Test ( > 5mW/cm
Caution!
Microwave radiation is dangerous. This tester can not
be compared with a high-tech device. The cost for
measuring devices like this are much larger. This is why
you should see this test only as an indication for possi-
bly existing microwave radiation.
- Switch your microwave on
- Touch the battery compartment lid (3) with one hand and guide
the test tip of the multitester slowly along the door of the
microwave. If the door seal is leaky, the LED will start blinking.
If this is the case, the microwave must not be operated any-
more. Take the device to a specialist.

Maintenance and Care

Separate the multitester from all power supplies before cleaning it or
carrying out maintenance. To clean the outside, only use a soft, dry
cleaning cloth. Do not get is damp or use cleaning agents. Mainte-
nance or repairs may only be carried out by an expert who is famil-
iar with the relevant regulations (VDE 100, VDE 0701) (VDE mark of
conformity).
Disposal
In the case of a defect, when the device can no longer be used, dis-
pose of it in accordance with current legal regulations.