Herunterladen Inhalt Inhalt Diese Seite drucken

Trouble Shooting; Fault Correction - Silvercrest PNTS 1400 E2 - IAN 275394 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

GB
IE
NI

Trouble shooting

Problem
Device does not start
Low or lack of suction
Float does not switch
the appliance off
Dust or dirt is blow out
of the device
14
Possible cause
Mains voltage is not
present
Defective on/off switch
(
6)
Worn carbon brushes
Defective motor
Hose system (
19) or jets
(
25/26) blocked
Suction pipe (
17)
assembled incorrectly
Container (
9) open
Container (
9) full
Filter (
21/23/24) full
or clogged
Float in the filter basket
(
27) does not move
Float in the filter basket
(
27) faulty
Float in the filter basket
(
27) does not move
Float in the filter basket
(
27) faulty
Filter (
21/23/24) is not
or not correctly assembled

Fault correction

Check plug socket, cable,
line, plug and fuse, where
appropriate, repair through
electrical specialist
Repair by Customer Care
Remove obstructions and
blockages
Assemble suction pipe correctly
Close container
Empty container
Empty, clean or replace filter
Release float
Repair by Customer Care
Release float
Repair by Customer Care
Use missing filters or check the
correct position of the filter