The period during which forced ventilation shall be activated daily (default
is off)
•
At what level to force ventilate (default is level 3)
•
The indoor temperature below which to heat (default is below 10°C)
•
The period for night reduction (default is none)
•
The temperature to reduce down to at night (default is 1°C)
Ventilation units WL610 or WL305 (roof ventilators):
Settings for air extraction mode
•
The air humidity above which air extraction mode shall start (default is
80%)
•
The indoor temperature from which air extraction mode shall start (default
is below 28°C)
•
If you have also installed indoor sensors (WGTHs): the indoor sensor that is
decisive for this function (otherwise, the indoor sensor is in the WS1000
Touch control unit)
•
At which level to ventilate (default is from level 1 to level 8, i.e. full use of
the gradation). The higher the indoor temperature and humidity lie above
the nominal value, the higher the level the ventilator switches to
•
The period during which forced ventilation shall be activated daily (default
is off)
•
At what level to force ventilate (default is level 3)
Settings for recirculation mode
•
The indoor temperature below which recirculation mode shall be started in
order to gain heat (default is deactivated). Basically, the recirculation
function only starts if the temperature at the ventilator is at least 3° warmer
than the indoor temperature
•
At what level the recirculation function shall be operated in order to gain
heat (default is level 3)
•
Activation of recirculation mode in order to prevent water condensation
(default is inactive) by pressing + or - and setting of the U value of
insulation glass. You can find out the U value from your conservatory
specialist.
•
At what level the recirculation function shall be operated in order to prevent
water condensation (default is level 4)
WFL supply air units:
•
The air humidity from which the supply air shall be opened (default is 80%)
112