Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications; Installation; Appliance Specification - CombiSteel 7455.0999 Gebrauchsanweisung

Vorschau ausblenden Andere Handbücher für 7455.0999:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4. SPECIFICATIONS

4.1 INSTALLATION

THIS EQUIPMENT MUST BE INSTALLED BY AN AUTHORIZED PERSON IN ACCORDANCE
WITH LOCAL AUTHORITY, GAS, ELECTRICITY, ANY APPLICABLE STATUTORY
REGULATIONS AND MANUFACTURER REQUIREMENTS.
NOTE: INSTALLATION IS THE RESPONSIBILITY OF THE OWNER
Gas Inlet Connection:
Gas Connection Point:
Gas Connection:
The authorized person installing this equipment must comply with local gas safety standard. Prescribed
requirements include, commission the equipment, gas leakage testing, operational checking and adjustments.
All units are tested and adjusted at the factory; however, all burners and pilots must be checked at the installed
location and adjusted as necessary.
Data Plate:
Installation Clearances: The MINIMUM clearance from combustible surfaces is;
Levelling:

4.2 APPLIANCE SPECIFICATION

Product name
Gas Category
Gas and Supply
Pressure
AT, BG, CR, CZ, DK, EE, FI, GR,
Country of
HR, HU, IS, IE, IT, LV, LT, NO, PT,
Destination
RO, SK, SI, ES, SE, CH, TR and GB
Injector Size
Gas Consumption
Warning: This appliance shall be installed in conformity with the current regulations and used only in a well-
ventilated location. Consult the instructions before installing and using this appliance.
1/2" BSP Female.
The gas connection point is located at the rear of the unit.
Details are shown in the drawings at the rear of this manual.
The appliance must be connected by an authorized person to the gas type specified
on the unit. The gas type is shown adjacent to the gas connection point on the rear
panel and on the data plate. Connect to and use only the correct type of gas.
The data plate is located at the rear of the fryer
Sides
150 mm, and
Rear
50mm
Adequate clearance must also be provided for service.
To adjust the legs to level the unit to the floor and/or to slightly adjust the height of
the unit, raise the front of the unit and adjust the legs (ensure safe work practices).
Similarly, raise the back of the unit and adjust the legs. DO NOT LAY THE UNIT ON ITS
BACK. ENSURE THE UNIT IS LEVEL.
Gas Fryer
I
2H
G20 at 20 mbar
Ø 2.3 mm
Ø 2.3 mm
www.combisteel.com
Type of appliances
I
2E
G20 at 20
G25 at 25
mbar
BE, FR
Ø 2.2 mm
Ø 2.2 mm
34kW for GF4 ; 27KW for GF3
Type A1
I
I
2L
2E+
G20/G25 at 20/25
mbar
mbar
NL
DE, LU, PL