Burner rating of ignition pilot: 750W
Nominal Gas Consumption Table for I2H only (reference only)
BURNER
GF4
GF3
Note: The pressure test point is located on the gas manifold (refer below).

4.3 TEST POINT PRESSURE

The pressure test point is located on the gas manifold and is accessed by opening the door. The test point
pressure is shown in the 'Nominal Gas Consumption Table' above and is set with the burners operating at
maximum setting.

4.4 VENTILATION AND AIR SUPPLY

All gas burners and pilots require sufficient air to operate. For optimum performance and for your safety, it is
ESSENTIAL that the equipment, in the installed position, has the proper air and ventilation and the correct
exhaust/canopy and air balance. The correct installation and compliance with all regulatory and other
requirements is the responsibility of the purchaser/owner.
Please note that a strong exhaust canopy will create a vacuum if there is insufficient replacement air. The amount
of air exhausted must be replaced by an equal amount of air. Airflow to the appliance must not be blocked or
restricted (e.g. large objects should not be placed in front of the appliance). The flue must never be covered or
restricted in any way.

4.5 DIMENSIONS

* Please note that the outside dimensions of GF3 and GF4 are identical.
* Product dimensions are 393 x 750x 1160 mm
* Packing dimensions are 510 x 820 x 1230 mm

4.6 ACCESSORIES

1.
Fry baskets
2.
Rack
3.
Oil extension pipe
4.
Clog clearance prod
5.
Operating manual
Test pressure at gas inlet
20 mbar
20 mbar
@ 2
@ 1
@ 1
@ 1
@ 1
www.combisteel.com
Test pressure at test point
13.5 mbar
14.7 mbar