F. AC current measurement (see figure 8)
Warning
To avoid electric shock, never measure current while the test leads are inserted into the
input terminals and disconnect test leads and tested circuit connection.
Never attempt an in-circuit current measurement where the open-circuit voltage be-
tween the circuit and the ground is greater than 600V.
User proper function, and range for the measurement.
To measure current, do the following:
1. Set the rotary switch to 20A~ ,200A~ or 600A~ .
2. Press the lever to open the transformer jaws.
3. Center the conductor within the transformer jaw, then release the Meter slowly until
the trasnformer jaw is completely closed. Make sure the conductor to be tested is
placed at the center of the transformer jaw, otherwise it will cause deviation. The Meter
can only measure one conductor at a time, to measure more than one conductor at a
time will cause deviation.
Note:
When current measurement has been completed,disconnect the connection between
the conductor under test and the jaw, and remove the conductor away from the trans-
former jaw of the Meter.
EN
(fig. 8)
29