b) Use with an External DMX Controller
Each DMX device in a DMX chain requires a so-called DMX starting address to be clearly identified by the
controller. This DMX starting address specifies the first DMX channel to which the effect light responds.
The remaining control channels come after this first DMX channel (DMX starting address).
The effect light requires 13 free DMX channels.
Setting the DMX starting address
• In the menu, select ADDR and push the ENTER (7) button.
• Select the desired starting address 001-512 with the UP (5) and DOWN (6) buttons.
• Push the ENTER button (7) to confirm your selection.
Setting the DMX operating mode
• In the menu, select MODE and push the ENTER (7) button.
• Select the operating mode DMX Ctrl with the UP (5) and DOWN (6) buttons.
• Push the ENTER button (7) to confirm your selection.
The following table provides information about the effects of the settings on the individual DMX channels.
DMX channel
Value
1
000-255
2
000-255
3
000-255
4
000-255
5
000-255
6
000-255
7
000-255
8
000-005
006-130
131-135
136-255
9
000-252
253-255
10
000-255
11
000-255
12
000-005
006-130
131-255
13
000-253
254-255
Function
Rotating movement PAN
Swivel movement TILT
Overall brightness
Brightness red
Brightness green
Brightness blue
Brightness white
Strobe effect off
Strobe effect 1 slow > fast
Strobe effect off
Strobe effect 2 slow > fast
Speed PAN/TILT movement
Light is switched off during PAN or TILT movements
Fine setting PAN
Fine setting TILT
Macro operation off
Colour macro 1 slow > fast
Colour macro 2 slow > fast
no function
Reset