WARRANTY CONDITIONS OF THE REFRIGERATION UNIT
Accident caused by installing in an environment containing oil (including
machine oil), water, salt (coastal area, etc.).
Accident caused by incorrect installation location (insufficient airflow, special
environmental condition such as water pressure, chemical substances, etc.).
Accident caused by adjustment error of control equipment, etc.
Accident caused by short cycle operation (each operation and stop for five min
or shorter).
Incorrect maintenance (not noticing gas leak).
Error in repair work (wrong component, missing component, wrong
attachment).
Accident caused by overcharging or shortage of refrigerant, and insufficient
refrigeration oil (starting failure, motor cooling failure, lubrication failure).
Accident caused by defrosting failure.
Accident caused by abnormal voltage.
When air or water is judged being contaminated in the cycle.
Accident caused by failure of power source caused by loose terminal of wiring.
Failure of the motor or electric component caused by abnormal power voltage
drop (220 V or below) when starting after power failure and switching to
emergency power source.
Failure of the motor or electrical component caused by abnormally high voltage
applied to the source such as lightening, or excessive noise such as arc spark,
etc.
Accident caused by unspecified voltage condition, or accident caused by
applying distorted voltage of a general-purpose inverter.
Accident caused by using a ground fault interrupter not specified by our
company.
Accident caused by not conforming to the range of evaporating temperature,
ambient temperature, and operating voltage specified for this product.
Accident caused by fire, earthquake, flood, lightening or other natural disaster.
When the product is operated on a vehicle, vessel, or transport means
(vibration, impact, momentary power failure, oil surface securing, etc.).
Accident caused by the installation or operation largely deviated from the
common sense general practice of installation, operation, adjustment, or
maintenance is not warranted. In addition, secondary damage caused by the
accident of the refrigeration machine, such as damaged food items or loss of
sales opportunity, is not compensated. Therefore, each user shall have an alarm
system for avoiding the secondary damage, or consult with our agent for
protective measures such as damage insurance.
Manufactured in France by PROFROID CARRIER S.C.S
178, rue du Fauge - ZI Les Paluds - B.P. 1152 - 13782 Aubagne Cedex - France
International : Tel. (33) 4 42 18 05 00 - Fax (33) 4 42 18 05 02